Viessmann Vitocal 100-AW

Vitocal 100-AW

Available at the End of May 2024

  • Includes a heat pump, indoor pumping station, and buffer tank.
  • Uses R32 (a new A2L refrigerant) – making this technology future-proof
  • Optional indirect tank for DHW, with a flat top that the buffer tank can sit on top of.

Technical Details

Heating capacity

20.5 MBH (6 kW) for AM2V-020028
34.0 MBH (10 kW) for AM2V-034043
58.0 MBH (17 kW) for AM2V-051078

Cooling capacity range (low – high)

1.4 – 1.5 tons (5.0 – 5.2 kW) for AM2V-020028
2.8 – 3.0 tons (9.8 – 10.5 kW) for AM2V-034043
4.2 – 4.3 tons (14.7 – 15.1 kW) for AM2V-051078

Efficiency ratio (EER)

16.81 for AM2V-020028
16.75 for AM2V-034043
14.46 for AM2V-051078

Coefficient of performance (COP)

4.927 for AM2V-020028
4.909 for AM2V-034043
4.238 for AM2V-051078

Refrigerant type

R32

Minimum outdoor air temperature

-13  °F (-25  °C)

Maximum outdoor air temperature

109 °F (43 °C)

Water flow rates for outdoor unit

3.7 – 8.8 GPM (0.85 – 2.0 m³/h) for AM2V-020028
6.2 – 15.0 GPM (1.4 – 3.4 m³/h) for AM2V-034043
11.4 – 25.5 GPM (2.6 – 5.8 m³/h) for AM2V-051078

Power supply for outdoor unit

208/230 VAC
1 Phase
60 Hertz

Total electrical load for outdoor unit

13.0 Amps for AM2V-020028
21.8 Amps for AM2V-034043
35.1 Amps for AM2V-051078

Dimensions of outdoor unit

Height
31¼ inches (795 mm) for AM2V-020028
36½ inches (928 mm) for AM2V-034043
52⅜ inches (1329 mm) for AM2V-051078

Width
46 inches (1165 mm) for AM2V-020028
50¾ inches (1285 mm) for AM2V-034043
49¼ inches (1250 mm) for AM2V-051078

Depth
15¾ inches (400 mm) for AM2V-020028
18⅛ inches (460 mm) for AM2V-034043
19½ inches (495 mm) for AM2V-051078

Weight
198 lbs (90 kg) for AM2V-020028
291 lbs (132 kg) for AM2V-034043
353 lbs (160 kg) for AM2V-051078

Power supply for indoor unit

230 VAC
1 Phase
60 Hertz

Amperage (FLA) for indoor unit

31 Amps for AM2V-020028 & AM2V-034043
43 Amps for AM2V-051078

Electric heater output for indoor unit

20,500 BTU (6 kW) for AM2V-020028 & AM2V-034043
30,700 BTU (9 kW) for AM2V-051078

Maximum operating temperature

165 °F (74  °C)

Maximum operating pressure

30 PSI (2 bar)

Dimensions of indoor unit

Height
28½ inches (723 mm)

Width
16¼ inches (416 mm)

Depth
12¾ inches (323 mm)

Weight
64 lbs (29 kg)

Hydronic connections

Indoor unit    
1¼ inch NPT (male threads)

Outdoor unit  
1 inch NPT (male threads)

Buffer tank capacity

20 USG (75 L)

Buffer tank water temperature range

45 to 230 °F (7 to 110 °C)

Buffer tank dimensions

Diameter
26½ inches (668 mm)

Height
21 inches (533 mm)

Weight
110 lbs (50 kg)

Warranty

Limited 5-year warranty for the compressor, 3-year warranty for individual components of the indoor unit and outdoor unit, and a 1-year warranty for the fittings.